Worth Data 802 RF Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Pomiary, testowanie i kontrola Worth Data 802 RF. FieldFox N9912A RF Analyzer Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 29
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Agilent FieldFox RF Analyzer
N9912A 4/6 GHz
Technical Overview
Carry precision with you.
Przeglądanie stron 0
1 2 3 4 5 6 ... 28 29

Podsumowanie treści

Strona 1 - Agilent FieldFox RF Analyzer

Agilent FieldFox RF Analyzer N9912A 4/6 GHzTechnical OverviewCarry precision with you.

Strona 2

Network analyzer time domainWith the time domain Option, FieldFox com-putes the inverse Fourier transform of the frequency-domain data to display re

Strona 3 - Handheld RF Analyzer

11sensorFieldFox can connect with the Agilent USB power sensors to make average power mea-surements up to 40 GHz. Using USB

Strona 4

testReturn loss/VSWR measurements allow you to evaluate

Strona 5

1313continuedIndependent signal sourceProvides a test signal to measure coverage, antenna isolation, long cable

Strona 6

14Transflective display makes it easy to read measurements in direct sunlightWater resistant chassis withstands wide temperature ranges and humid envir

Strona 7

FieldFoxWarranted performance. Specifications include guardbands to account for the expected statistical performance distributio

Strona 8

16FieldFox  2 MHz to 4 GHz 60 dB (typical) > 4 GHz to 6 GHz 55 dB (typical) 

Strona 9

17FieldFox Return loss  0 to 100 dB Resolution 0.01 dB   0 to 100 Resolution

Strona 10 - FieldFox

FieldFox S11 Vector measurement, S11 magnitude and S11 phase. Specification is listed under Cable and antenna

Strona 11

19FieldFoxFrequency Frequency range    100 kHz to 4 GHz, usable to 5 kHz  100 kHz to 6

Strona 12

2FieldFoxEvery piece of gear in your kit had to prove its worth. Measuring up and earning a spot is the driving idea behind Agilent’s FieldFox RF anal

Strona 13

Amplitude Measurement range Displayed average noise level (DANL) to +20 dBm Input attenuator range 0 to 31 dB, 1 dB steps 

Strona 14

 Two -30 dBm tones at input mixer, > 100 kHz tone separation < -96 dBc, +18 dBm TOI (nomina

Strona 15

Channel power meter is a built-in power measurement that does not require an external power sensor. Users can set the

Strona 16

23FieldFox23General specifications  Type-N (female) Input impedance 50 ohm External reference Input type BNC female R

Strona 17

24General specifications continued Environmental Meets MIL-PRF-28800F Class 2 specification Humidity  Temperature   

Strona 18

N9912A FieldFox RF analyzerFieldFox RF Analyzer base functions: One port cable and antenna analyzer (4 GHz), broadband calibration, CalReady, sta

Strona 19

26  N9910X-800 T-calibration kit, DC to 6 GHz, Type-N (m) N9910X-801 T-calibration kit, DC to 6 GHz,

Strona 20

FieldFox27FieldFox Accessories

Strona 21

FieldFoxSoft carrying case with backpack and shoulder straps included with a standard N9912A. FieldFox

Strona 22

For more information on Agilent Technologies’ products, applications or services, please con-tact your local Agilent office. The complete list is avai

Strona 23

3Key differentiatorsIntegrated QuickCal calibrates without a calibration kit CalReady

Strona 24

44FieldFoxBacklit keypadquick marker fu

Strona 25

FieldFox2.8” D72 mmExternal referenceand external triggerSpacious connector design makes connections fast and simpleRF connec

Strona 26

6Key MeasurementsFifty to sixty percent of cell site problems are caused by faulty cables, connectors, and antennas. Degrade

Strona 27

7Measurements in the field without the need to manually calibrateEach instrument is CalReady at the RF Out port, immediately following power-on or pres

Strona 28

Built-in spectrum analyzerInterference is a major source of cell site problems. Interference can be internal or external, and uplink or downlink. Dow

Strona 29 - Certified

9Independent signal source and tracking generatorFieldFox has a built-in independent signal source, with a frequency range of 2 MHz to 4/6 GHz. The si